Bimeq® SEAL

Roofing putty

Technical data
Composition asphalt, synthetic rubber, reinforcing fibres, additives
Dry residue content >75%
Application temperature from +5°C to + 35°C
Dust dry 3-4 hours
Application

Prior to application in low temperatures, leave for 24 hours in a warm room. Intended for cold application.

Repair works: fill in any defects with Bimeq® SEAL using a trowel, by applying a layer 2-5 mm thick.

Seamless sealing: apply with a metal trowel ensuring uniform layer thickness. Apply two thin coats to eliminate accidental irregularities and errors during application. Each layer should be 2-3 mm thick.

Storage

Keep only in the original closed containers in a cool, dry place. Can be stored in temperatures below 0oC. Protect from direct sunlight. Expiration date: 12 months from the production date specified on the packaging.

  

Technical data and application information is provided for temperatures of 23°C ±2°C and air humidity of 50-60%. In other conditions, the drying time may change. The product contains organic solvents – during product application ensure suitable ventilation of the working area. Works must be performed in line with Health and Safety rules resulting from MSDS and labels on packaging.